Our products: vertical turbine pump, vertical wet pit pump, vertical oil sump pump, vertical condensation pump, right Angle gearbox
date:2021/1/14 22:20:26 source: Vertical Turbine Pump Manufacturer and Vertical Suspension Pump Prices Provider visits()
Axial-flow pumps are low-head high-flow designs and aren’t true turbines pump. However, from the outside looking in, axial-flow pumps look a lot like turbine pumps, so we’ve included them in this category. Axial-flow pumps are typically designed for heads no greater than approximately 30 Ft and are often designed to lift water just a dozen feet. They are common in flood-control applications. Z(H)LB vertical axial-(mixed)-flow pump is a new generaleration product successfully developed by this Company by Adopted standard: GB/T13008 Technical conditions for mixed-flow pump and axial-flow pump Purpose: Extensively used for hydraulic projects, farm-land irrigation, industrial water transportation, water supply and drainage of cities and water allocation engineering. Conditions for use: Suitable for pumping pure water or other liquids of the phy About the structure: ZLB(Q),HLB(Q) series products are all of a vertical structure and fitted with a vertical motor, With the impeller there are fixed, semi-adjustable and fully-adjustable type. The fixed type means both impeller and hub are cast integrally and the impeller angle is unadjustable; the semi-adjustable type means the impeller can be turned to the desired angle by loosening the fixing screw on it in case the working conditions need to be changed, then fix all the impellers again; Z(H)LQ is the fully-adjustable type, that means the impeller angle can be adjusted through a mechanical Vertical axial-(mixed)-flow pump consists of the pump casing and the actuating part. The pump casing generally includes water inlet pipe, impeller, guide vane, pump shaft, elbow, middle pipe, sealing unit and clutch. For both middle and small pumps, a water inlet horn is used as the water inlet pipe while, for the large one, a toggle or bell water inlet passage is used, poured with concrete and fitted with imported basic parts. The adjustable impeller is formed with blade(stainless steel or copper alloy, in general), hub, water guide cone. For the middle and small pumps, both impeller and pump shaft are connected with flat pin and nut while, for the large and fully adjustable ones, a flange is used to connect both hub and main shaft. The pump s guide bearing is a rubber one and can be lubricated with going-through water or additional pure water. When lubricated with the going-through water, it has to be done to supply water for the rubber bearing on the upper side via a water-led pipe and do not stop until water comes out of the pump normally. The said series pumps are used to transfer clear water,rain water,water in iron sheet pits,sewage and seawater,servicing in power plants,iron and steel works,water supply companies,sewage treatment plants,petroleum and chemical industries,mines as well as municipal water supply and drainage projects,farmlands irriagation,flood protection and drain waterlogged farmlands,etc..The temperature of pumped media is below 55°C and reaches to 90°C for special design. The flow rate ranges from 30 to 20000m3/h and the head—from 7 to 200m. Features 1. Operation smooth,safe and reliable,starting without exhausting vacumn,service life long. 2. Flowing channel simple and reliable,saving the investment for construction of the pump house. 3. Easy to be installed and dismantled. Easy to be maintained and inspected. 4. High efficiency and help saving the cost. Model description 500HLBK2000-23 500—Outlet of the pump:500mm HLBK----Vertical Axial Flow Impeller Pumps 2000----Designed flow rate at 2000 cubic meters per hour 23---Designed head at 23 meters Structure feature: 1. Series HLBK pumps are of vertical single stage axial flow pump 2. The following structure types are available for the pump:the discharge opening above and/or under the mounting foundation(Type Code named S and X respectively);the axial thrust force born by the pump and/or by the motor(Type Code named T and D);lubricating water from outside and/or from the pump itself. 3. The intake sump is of wet pit and/or dry pit types. Wet pit type:lower part of the pump inundated in the intake sump. Dry pit type:the water enters into the pump,the suction bellmouth is connected with the inlet pipe of the pump by means of elbow bend pipe of 90. 4. Rubber guide bearings and /or the Thordon guide bearings are available for bearings of the pump. 5. Generally when the nozzle diameter of the pump is under 1000mm , non pull-out type is adopted for the rotor and the discharge opening is above the mounting foundation(Type Code named ST). In this case the axial thrust force and the weight of the rotor are usually born by thrust bearings of the pump itself and flexible connection is adopted between the pump and the motor.The thrust force and the weight of the rotor can also be born by the motor if required,or other structure types such as SD,XT,XD are available .Rotor pull-out type can also be adopted if required by clients. Generally when the discharge diameter of the pump is above 1000mm, pull-out type is adopted for the rotor and the discharge opening is under the mounting foundation(Type Code named XD).In this case the axial thrust force and the weight of the rotor are usually born by thrust bearings of the motor and rigid connection is adopted between the pump and the motor. The axial thrust force and the weight of the rotor can also be born by the pump if required,or other structure types such as XT,SD,ST are available .Rotor non pull-out type can also be adopted if required by clients. 6. When the axial thrust force and the weight of the rotor are born by pump itself,the thrust bearing of the pump is lubricated with dilute oil and is equipped with a temperature detector Pt100 to detect bearing temperature and a pressure type thermometer to detect the temperature of lubricating oil. 7. The antielectrochemical corrosion appliance is adopted for the part of the pump contacting the liquid to ensure the service life of the pump when seawater is pumped. 8. The packing seal is adopted for the axial seal of the pump. 9. The clearance between the impeller and the impeller chamber,i.e.the rotating component and the static component,can be easily adjusted on the pump mounting foundation. Materials Of Major Parts Major Parts Clear water Seawater Sewage(incl.of abrasiv powder) Discharge elbow Intermediate column (internal & external) Q235-A HT200Ni2Cr 0Cr18Ni9 ZG0Cr18Ni12Mo2 Q235-A Guide vane, Suction bellmouth HT200 HT200Ni2Cr ZG0Cr18Ni9 ZG0Cr18Ni12Mo2 HT200、QT500-7 ZG1Cr13Ni1 Impeller ZG1Cr13Ni1 HT200 ZG0Cr18Ni9 ZG0Cr18Ni12Mo2 QT500-7 ZG1Cr13Ni1 Shroud,wearing ring HT200 ZG2Cr13 ZG0Cr18Ni9 ZG0Cr18Ni12Mo2 ZG1Cr13Ni1 QT500-7 Main shaft 45、2Cr13 2Cr13、0Cr18Ni9 0Cr18Ni12Mo2 45、2Cr13 1Cr18Ni9 Shaft sleeve 45,2Cr13 2Cr13、0Cr18Ni9 ZG0Cr18Ni12Mo2 2Cr13、1Cr18Ni9 Guide bearing HT200+abrasive rubber HT200+Thordon bearing HT200+abrasive rubber HT200+Thordon bearing HT200+abrasive rubber HT200+Thordon bearing Remarks:Other materials are available at the request of clients.Cast iron is suitable only for closed type impeller. Vertical Axial Flow Impeller Pumps
means of introducing the advanced foreign and domestic knowhow and meticulous designing on the basis of the requirements
from users and the conditions of use. This series product uses
the latest excellent hydraulic model, wide range of high efficacy,
stable performance and good vapor erosion resistance; the
impeller is precisely cast with a wax mould, a smooth and
unimpeded surface, identical accuracy of the cast dimension to
that in design, greatly reduced hydraulic friction loss and
shocking loss, a better balance of impeller, a higher efficiency
than that of the common impellers by 3-5%.
Flow:800~200000m /h
Head:1~30.6m
Power:18.5~7000kWVoltage: 355kW
Frequency:50Hz6kV 10kV
-sical chemical natures similar to those of pure water.
Medium temperature: 50
Medium density: 1.05 10 kg/m
PH value of medium:between 5~11
or hydraulic adjustor with or without stopping.
Both middle and small pumps are directly actuated by a vertical motor, the motor is mounted on the motor seat and connected with the actuating shaft via an elastic cluth. Inside of the motor seat
there are radial and thrust bearings, lubricated with engine oil or grease; for the one of a bigger power there is a water cooling mezzanine. Large pump is fitted with a large vertical motor, directly mounted on the motor s basic beam, and both motor shaft flange and pump shaft flange (hinged hole) are linked withbolt. The axial force of the pump is borne by the thrust bearing
of the large vertical motor.The pump moves clockwise viewing from the motor. Description